MOULDED CASE CIRCUIT BREAKER NSX100H 3P WITHOUT TRIP UNIT

Product code
3653002
Circuit breaker Compact NSX100H, 100A, 3p, without trip unit
Circuit breaker Compact NSX100H, 100A, 3p, without trip unit. range: Compact - range of product: NSX100...250 - product or component type: basic frame - device short name: Compact NSX100H - circuit breaker name: Compact NSX100H - network type: AC - network frequency: 50/60 Hz - breaking capacity code: H - breaking capacity: at 240 V AC 50/60 Hz conforming to NEMA AB1, at 240 V AC 50/60 Hz conforming to UL 508, at 480 V AC 50/60 Hz conforming to NEMA AB1, at 480 V AC 50/60 Hz conforming to UL 508, at 600 V AC 50/60 Hz conforming to NEMA AB1, at 600 V AC 50/60 Hz conforming to UL 508, Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2, Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - [Ics] rated service breaking capacity: at 220/240 V AC IEC 60947-2 50/60 Hz conforming to IEC 60947-2 IEC 60947-2, at 380/415 V AC IEC 60947-2 50/60 Hz conforming to IEC 60947-2 IEC 60947-2, at 440 V AC IEC 60947-2 50/60 Hz conforming to IEC 60947-2 IEC 60947-2, at 500 V AC IEC 60947-2 50/60 Hz conforming to IEC 60947-2 IEC 60947-2, at 525 V AC IEC 60947-2 50/60 Hz conforming to IEC 60947-2 IEC 60947-2, at 660/690 V AC IEC 60947-2 50/60 Hz conforming to IEC 60947-2 IEC 60947-2 - suitability for isolation: yes conforming to EN 60947-2, yes conforming to IEC 60947-2 - utilisation category: category A. Benefits: Always first, Integrated power monitoring unit: Energy efficient, New breaking capacities: Performance, Interchangeable: Increased safety, Simple installation procedures: Easy to install.. Applications: - Commercial buildings, Hospitals, Steel industry, Marine..

Product details

Technical specifications

Rated permanent current Iu100 A
Rated voltage690 ... 690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70 kA
Overload release current setting0 ... 0 A
Adjustment range short-term delayed short-circuit release0 ... 0 A
Adjustment range undelayed short-circuit release0 ... 0 A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionfalse
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingfalse
DIN rail (top hat rail) mounting optionalfalse
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
With switched-off indicatorfalse

Product codes

SAPAIT507
PLC3653002
STK3653002
GTIN/EAN3606480006524
Manufacturer part numberLV429004
Vendor material numberLV429004

Basic information

Package measurements (L x W x H)120 x 190 x 135 mm
Package volume3.078 l
Package weight1.45 kg
Base uniteach
Package units1 / 15
Package contents
UNSPSC39121616
BrandSCHNEIDER ELECTRIC
VendorSCHNEIDER ELECTRIC FINLAND OY